Uploaded image for project: 'Artifactory Binary Repository'
  1. Artifactory Binary Repository
  2. RTFACT-18486

upload followed by cancel to HA triggers mail to admin

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Normal
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: 6.8.0
    • Component/s: None
    • Labels:
      None

      Description

      steps to reproduce:

       

      1. install HA with two nodes configured with with cluster-file-system and redundancy of 2 
      2. install mail server and connect artifactory to this mail server
      3. use the default binary provider config: <config version="2">
            <chain template="cluster-file-system"/>
        </config>

      4. upload large file
      5. break the upload half way
      6. see there is email about this error

      This is caused due to the binary provider being marked as inactive and therefore notify the admin via with mail.

       

       

       

        Attachments

          Issue Links

            Activity

              People

              Assignee:
              yoazm Yoaz Menda (Inactive)
              Reporter:
              yoazm Yoaz Menda (Inactive)
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

                Dates

                Created:
                Updated:
                Resolved: